Air Filtration for Air Logic (User-Supplied)
- 5 micron (Min.) Filtration Required, Clean & Dry Air
Air Filtration for Atomizing Air (User-Supplied)
- 30 micron (Min.) Filtration Required, Clean & Dry Air
Air Supply
- 0.6 - 0.7 MPa, 6.0 - 7.0 bar
Air-Assisted Spray Systems
External Power Supply Requirements
- 90-250 Vac, 50/60 Hz, 7 Amps Max.
Fluid Filtration (User-Supplied)
Fluids Handled
- One or Two Component Solvent & Waterborne Paints, Polyurethanes, Epoxies, Acid Catalyzed Varnishes, Moisture Sensitive Isocyanates
Maximum Fluid Flow
- 800 cc/minute (Depending on Material Viscosity)
Maximum Working Air Pressure
MC0500
- Pumps sold separately, see selected pump manual for wetted parts information.
MC1000 & MC2000
- 17-4 PH, 303, 304 Stainless Steel, Tungsten Carbide (with Nickel Binder), Perfluoroelastomer, PTFE, PPS, UHMWPE
MC3000 & MC4000
- 316 Stainless Steel, 17-4 PH Stainless Steel, PEEK, Perfluoroelastomer, PTFE, PPS, UHMWPE
Operating Temperature Range
Storage Temperature Range
Systems with High-Pressure Pumps
Systems with Low-Pressure Pumps
Wetted Parts
- 17-4 PH, 303, 304 Stainless Steel, Tungsten Carbide (with Nickel Binder), Perfluoroelastomer, PTFE, PPS, UHMWPE