Amperage Requirement
- See Systems Page in Instruction Manual.
Fluid Circulation Ports
- 1/4 Male NPSM, with Plastic Tubing, (1.75 MPa, 17.5 bar) Max.
Fluid Inlets
- Component A (ISO): 1/2” NPT Female, (1.75 MPa, 17.5 bar) Max.
Fluid Outlets
- Component A (ISO): #8 (1/2”) JIC, with #5 (5/16”) JIC Adapter. Component B (RES): #10 (5/8”) JIC, with #6 (3/8”) JIC Adapter
Fluid: Oil Pressure Ratio
- Models H-25 & H-40:1.91:1. Model H-50:1.64:1. Models H-XP2 & H-XP3:2.79:1
Heater Power (A & B Heaters Total, No Hose)
- See Systems Page in Instruction Manual.
Hydraulic Reservoir Capacity
Line Voltage Requirement
- 230 V 1-Phase & 230 V 3-Phase Units: 195-264 Vac, 50/60 Hz 400 V 3-Phase Units: 338-457 Vac, 50/60 Hz
Maximum Fluid Temperature
Maximum Fluid Working Pressure
- Models H-25 & H-40: (13.8 MPa, 138 bar) Model H-50 1-Phase: (11.7 MPa, 11.7 bar) Model H-50 3-Phase: (13.8 MPa, 138 bar) Models H-XP2 & H-XP3: (24.1 MPa, 241 bar)
Maximum Output (10 Weight Oil at Ambient Temperature)
- Model H-25: 22 lbs/min (10 kg/min) (60 Hz). Model H-XP2: 1.5 gpm (5.7 Liter/min) (60 Hz). Model H-50: 52 lbs/min (24 kg/min) (60 Hz). Model H-40: 45 lbs/min (20 kg/min) (60 Hz). Model H-XP3: 2.8 gpm (10.6 Liter/min) (60 Hz)
Output Per Cycle, A & B
- Models H-25 & H-40: (0.23 Liter). Model H-50: (0.28 Liter). Models H-XP2 & H-XP3: (0.16 Liter)
Recommended Hydraulic Fluid
- Citgo A/W Hydraulic Oil, ISO Grade 46
Sound Power, Per ISO 9614-2
Sound Pressure, 1 m from Equipment
Weight
- Units with 8.0 KW Heaters: (243 kg). Units with 12.0 KW Heaters: (271 kg). Units with 15.3 KW Heaters (H-25/H-XP2 Models): (255 kg). Units with 15.3 KW Heaters (H-40/H-XP3/H-50 Models): (271 kg). Units with 20.4 KW Heaters: (271 kg)
Wetted Parts
- Aluminum, Stainless Steel, Zinc-Plated Carbon Steel, Brass, Carbide, Chrome, Fluoroelastomer, PTFE, Ultra-High Molecular Weight Polyethylene, Chemically Resistant O-Rings