G3 Max Automatic Lubrication for Series Progressive & Injector-Based Systems

Brand: Graco, Inc

G3’s flexible design works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Three controllers to choose from with multiple zone and feedback options. Includes one adjustable pump element–standard, plus room for two more. Multiple reservoir choices and more! The ultimate in flexibility–for a high value, custom fit on your application. Work faster and smarter with Graco’s exclusive Data Management System (DMS™). Find out exactly how your lubrication system is performing and how well it’s lubricated. Tracks history, provides data protection, upload or download data using a simple USB flash drive.
Features
  • Built-in controller with selectable pump on/pump off timer.
  • Low level indicator provides low warning and shut-down alarm.
  • Manual run initiates lube cycle on-demand (remote option also available).
  • Password protection safeguards.
  • Pre-lube function can initiate lube cycle on start-up.
  • Up to three pressure or cycle switch inputs to ensure proper lubrication cycles.
  • Mix/match cycle and pressure switches for custom installations and feedback.
  • Machine count input–ideally suited for inconsistently used equipment.
  • Fault indication to external alarms.
  • Optional Data Management System™ (DMS).
  • Specifications

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Ambient Temperatures

    • -25° to 70° C

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Cycle Rate

    • 8.0 Hz (50 % Duty Cycle)

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Fluid Grease Models

    • Grease NLGI 000 - #2

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Fluid Oil Models

    • At Least 40 cSt Oil. Oil Units with Low Level Must have at Least 80 cSt

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Input Impedance

    • 1.1

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - IP Rating

    • IP69K

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Load Current 100/240 Vac

    • 22 mA @ 24 Vdc

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Load Current 12 Vdc

    • 11 mA @ 12 Vdc

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Load Current 24 Vdc

    • 22 mA @ 24 Vdc

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Maximum Off Current 100/240 Vac

    • 1.5 mA

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Maximum Off Current 12 Vdc

    • 1 mA

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Maximum Off Current 24 Vdc

    • 1.5 mA

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Maximum Residual Voltage 100/240 Vac

    • 4 V

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Maximum Residual Voltage 12 Vdc

    • 2 V

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Maximum Residual Voltage 24 Vdc

    • 4 V

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Pump Outlet

    • 1/4-18 NPSF. Mates with 1/4-18 Male NPT Fittings

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Pump Output - 0 Spacers

    • 0.25” 3 (4 cm³)/Min Per Outlet - 0 Spacers

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Pump Output - 1 Spacer

    • 0.18” 3 (3 cm³)/Min Per Outlet - 1 Spacer

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Pump Output - 2 Spacers

    • 0.12 Sq inch (2 Sq cm)/Min Per Outlet - 2 Spacer

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Pumps

    • Up to 3

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Required Switch Type

    • Normally Open (Sink, Source, or Dry Contact)

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Reservoir Size

    • 2 L

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Response Time

    • 60 milliseconds

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Sensor Inputs

    • 1 (Machine Count)
    • 3 (Any of Pressure or Cycle)

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Sensor Voltage 100/240 Vac

    • 24 Vdc

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Sensor Voltage 12 Vdc

    • Input Voltage

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Sensor Voltage 24 Vdc

    • Input Voltage

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Sound Data

    • Amp, Lt, 60 dB

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Weight (Dry - Includes Power Cord & Plug) with Follower Plate

    • 6.44 kg

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Weight (Dry - Includes Power Cord & Plug) without Follower Plate

    • 6.03 kg

    Inputs - Cycle Pressure, 1, 2, 3, Machine Count - Wetted Parts

    • Nylon 6/6 (pa), Trogamid T5004-060, Zinc-Plated Steel, Carbon Steel, Alloy Steel, Stainless Steel, Nitrile Rubber (Buna-N), Bronze, Nickel-Plated Alnico, Chemically Lubricated Acetal, Aluminum, PTFE, Grillamid

    Maximum Working Pressure - Maximum Working Pressure

    • 35.1 MPa, 351.6 bar

    Outputs - Alarm Relay - Maximum Operating Current

    • Resistive: 3 A (AC), 3 A (DC), Inductive: 1.5 A (AC), 1.5 A (DC)

    Outputs - Alarm Relay - Maximum Operating Voltage

    • Resistive: 250 Vac, 220 Vac, Inductive: 250 Vac, 220 Vdc

    Outputs - Alarm Relay - Maximum Switching Capacity

    • Resistive: 50 VA, 60 W, Inductive: 25 VA, 30 W

    Outputs - Alarm Relay - Minimum Permissible Load

    • Resistive: 10 μA, 10 M Vdc, Inductive: 10 μA, 10 M Vdc

    Outputs - Alarm Relay - Rated Load

    • Resistive: 0.4 A at 125 Vac, 2 A at 30 Vdc, Inductive: 0.2 A at 125 Vac, 1 A at 30 Vdc

    Outputs - Low Level (Dry Contact) - Carry Current

    • 1.2 A, Max.

    Outputs - Low Level (Dry Contact) - Contact Rating

    • 10 Watts, Max.

    Outputs - Low Level (Dry Contact) - Switch Rating

    • 200 Vdc, Max.

    Outputs - Low Level (Dry Contact) - Switching Current

    • 0.5 A, Max.

    Outputs - Vent Valve - Maximum Operating Current

    • 2 A

    Outputs - Vent Valve - Maximum Operating Power

    • 48 W

    Outputs - Vent Valve - Output Voltage 100/240 Vac

    • 24 Vdc

    Outputs - Vent Valve - Output Voltage 12 Vdc

    • Input Voltage

    Outputs - Vent Valve - Output Voltage 24 Vdc

    • Input Voltage

    Outputs - Vent Valve - Required Vent Valve Type

    • Normally Closed

    Power - 100-240 Vac

    • 88 - 264 Vac, 0.8 A Current, 90 VA Power, 47/63 Hz, Single-Phase

    Power - 12 Vdc

    • 9 - 16 Vdc, 5 A Current, 60 W, Inrush/Locked Rotor 12 A

    Power - 24 Vdc

    • 18 - 32 Vdc, 2.5 A Current, 60 W, Inrush/Locked Rotor 6 A

    Documentation

    Document

    Instructions

    show more