Quartz QN Series Valve Position Monitor

Brand: Valmet

The Quartz is available in explosionproof (QX), nonincendive, intrinsically safe (QN), and general-purpose (QG) versions.

The robust epoxy-coated anodized aluminum construction, and optional stainless steel version, makes this platform extremely durable and well suited for use in corrosive, heavy washdown environments.

QN: Nonincendive is approved for all div.2/zone 2 hazardous environments with proximity sensors using a clear cover. Intrinsically safe Namur sensors or passive switches are available for div.1/zone 0 applications.
Features
  • Rapid enclosure access Screw-on cover allows quick enclosure access, saving you valuable maintenance and set-up time. The cover provides a vaportight seal and allows entry to internal components in less than five seconds.
  • Faster wiring Pre-wired and labeled terminal strip enables quick, convenient attachment of field wires.
  • Quick set cams are easy to adjust Touch and tune switch settings allow you to make adjustments in seconds without the use of tools.
  • Dual shaft o-ring seals eliminate corrosion Top inner and bottom outer shaft o-rings seal the drive bushing from both external corrosives and internal contaminants that enter the enclosure.
  • Special drive bushing assures long cycle life The oil impregnated bronze bushing maintains smooth operation and eliminates the potential for shaft seizure due to actuator shaft eccentricity.

Specifications

Brand

Approvals & Certifications

  • ATEX II 1 G Ex ia IIC T6 to T1 Ga Ta, IP67
  • CCoE Ex ia IIC T6 to T1 Ga, Ta
  • CE 1725
  • FM Class I, Div. 2, Grade A, B, C, D & Class II, Div. 2, Groups F, G
  • FM Intrinsically Safe Class I,II,III, Div. 1 Grade A, B, C, D, E, F, G
  • IEC 61508 Parts 1-7: 2010 & IEC 61511-1: 2003 + Corr. 1: 2004
  • TR CU 0Ex ia IIC T6 to T1  Ga X, IP67

Communication

  • Baud Rate: 125K, 250K or 500K

Conduit Connection

  • 1/2” NPT
  • 3/4” NPT
  • M20

Configuration

  • Auxiliary Discrete Input
  • Discrete Input
  • Discrete Sensor Input
  • Modified Output Block
  • Multiple DI/DO Blocks
  • Power Output
  • Single-Pole Double-Throw
  • Single-Pole Single-Throw
  • Solid State Sensor
  • Wire Terminations

Cover Material

  • Lexan

Current

  • NAMUR Sensor 45 Current Ratings: Target Off I< 3 mA
  • NAMUR Sensor 45 Current Ratings: Target on I< 1 mA
  • Stainless Steel Sensors 35 Min. on Current: 0.5 mA
  • Stainless Steel Sensors 35, Max.
  • Stainless Steel Switching Sensors (_X) Min. on Current: 2 mA
  • Stainless Steel Switching Sensors (_X) - Max.
  • VCT with Extended Addressing, Max.
  • VCT, Max.

Display

  • LEDs

Elastomers

  • Buna-N

Electrical Rating

  • 14 Switch (Mechanical Switch) Electrical Rating: 24-125 Vdc
  • 14 Switch (Mechanical Switch) Electrical Rating: 4.5 A at 125/250 Vac
  • G Switch Electrical Rating: 0.2 A at 120 Vac
  • G Switch Electrical Rating: 0.3 A at 24 Vdc
  • Gold Contacts (_W Switch) Electrical Rating: 0.5 A at 30 Vdc
  • Gold Contacts (_W Switch) Electrical Rating: 1 A at 125 Vac
  • H Switch Electrical Rating: 100 W, Max.
  • H Switch Electrical Rating: 240 V, Max.
  • J & M Switch Electrical Ratings: 0.1 A at 10-30 Vdc
  • P Switch Electrical Ratings: 0.15 A at 125 Vac / 30 Vdc
  • S Switch Electrical Rating: 0.1 A at 120 Vac
  • S Switch Electrical Rating: 0.1 A at 24 Vdc
  • Silver Contacts (_V Switch) Electrical Rating: 0.5 A at 125 Vdc
  • Silver Contacts (_V Switch) Electrical Ratings: 10 A at 125/250 Vac

Environmental Protection

  • IP66
  • IP67
  • NEMA 4
  • NEMA 4X
  • NEMA 6

Indication

  • Red/Green

Input

  • 24 Vdc at 2 mA

Load

  • 683 ohms at 24 Vdc
  • 700 ohms at 24 Vdc

Materials of Construction

  • Drive Bushing: Bronze, Oil Impregnated
  • Fasteners: Stainless Steel
  • G, M & S Switch Contact Composition: Rhodium
  • H Switch Contact Composition: Tungsten
  • J & P Switch Contact Composition: Ruthenium

Operation

  • Normally Closed (Solid State)
  • Normally Open (Solid State)

Output

  • 4-20 mA
  • DeviceNet Output: 4 W at 24 Vdc Outputs Combined
  • VCT Bus Powered Output: 2 mA at 6.5 Vdc Each, Current Limited to 2 mA (Bus Powered)
  • VCT with Extended Addressing Output: 2 W at 24 Vdc

Power Requirement

  • 10-40 Vdc

Range

  • 35° to 270°
  • 35° to 320°

Seal Type

  • Hermetically Sealed

Temperature Range

  • -40° to 80° C (-40° to 176° F)

Voltage

  • 20-250 Vac
  • 5-250 Vdc

Voltage Drop

  • G, H, J, M & P Switch, Max.
  • G, H, J, M, P Switch, Max.
  • S Switch, Max.
  • Stainless Steel Sensors 35, Max.
show more